|
|
HOW TO INSTALL YOUR
|
![]() |
|
This Equipment is designed for Wall Mounting Only The unit must be located on a flat surface:- 1. Remove the face panel via the four screws located in the corners. 2. Drill the rear of the case in a minimum of two places to suit the precise location of the unit ensuring the cable gland is positioned at the bottom. 3. Use suitable screws to affix to the desired location. 4. Pass all cables through the cable gland and affix the green connector plugs as detailed above. 5. Plug the connectors into the correct sockets on the rear of the face panel and relocated using the four screws to fasten the face to the case. NOTE: Do not over tighten the corner screws. Wiring Instructions Connect the controller using the Green plugs provided as per the above wiring diagram making sure the power supply is via a standard three pin 13 amp plug fitted with a 13 amp fuse and a Residual Current Circuit Breaker. Pass all cables through the cable gland by making a small slit with a sharp knife. NOTE: The supplied cable gland must be used and be located at the bottom of the unit. Initial Setting and Configuration This unit has been factory set to the following configuration with the exception of the set point which was set at 85 degrees F for testing purposes only. The controller is set to Heating mode. Read out is in degrees Fahrenheit. Differential has been set at 1 degree F. and the maximum allowable set point temperature has been restricted to 100 degrees F. |
|
Copyright © 2002 East Riding Koi Co. - Design by Stars N Sites |